Wednesday 17 January 2018

rotary four way valves

Mariners Repository

Collection of notes and literature on various topics ,simplified and presented as a one stop search .

I always believed in the fact that knowledge expands by sharing and proactive learning, and is a lifetime process. Concept based learning is the best way to understand and grow further . Knowledge is vast and scattered all over the net and in physical form of books .It takes effort, time and dedication to bring all in one place. This is a sincere effort to bring all my notes and collection over a period of two decades, simplified and open to all students and professionals . It will always be my sincere endeavor to update the pages from time to time as per technical advances , with support from colleagues, students , academia , professionals and fraternity in the industry.

Hydraulics Part 1 - Direction Control Valves

Direction control valves in Hydraulic systems are classified as follows:
1.Type of internal element for actuation : Poppet (piston or ball) , Rotary spool , sliding spool
2.Methods of Actuation : Manual , mechanical , Pneumatic , Hydraulic , electrical , Electronic or a 
   combination
3.Size : Nominal size , volume handled
4.Type of connection  :Flanged , Pipe thread

Hydraulic notation




Check Valves :
These are the simplest type of hydraulic valves - allowing free flow in one direction and blocking the other side.There is a light spring holding the poppet valve in position , only to be lifted up when flow occurs overcoming the spring pressure in that direction.These are further classified based on direction as 
In line check valve (flow direction is in the same axis) 
-Right angle check valve  flow direction is  in right angles to the original flow.

Restricted flow check valve - has an orifice in the valve plate .These valves are used to control the rate of pressure rise or fall in a system.

Pilot operated check valves - need a pilot pressure to actuate the check valve




A typical application of pilot operated check valves - is accumulator unit powered by pump- as shown below.

Symbols







Methods of actuation:
Mechanical Actuation
 Pneumatic/ Hydraulic
 Electrical / Electronic actuation : By solenoids AC/DC , controlled by electronic logic.




The number of ports to and from determines a Two way , Three way or four way valve
Valves with machined spool (2 Way , 3 Way , 4 way valves )
Two way valves permit the flow from one pressure port to outlet port by change of spool




Three way valve have special spool configurations , permitting flow from pressure to two other ports at the same time.
Four way valves are present in five  variations


1. Spring centered : 
Two position spring centered has one actuator with spring to return
Three position spring centered has two actuators- with spring to return.


 2.Two position spring offset : Spring holds the spool at one position and actuator changes condition opposite to spring condition


3.Two position Actuate to center  : Valve is normally under one extreme condition held by spring - only to return to center position when actuated


 4.Two position Detented : Valve spool is held in position by detent mechanism in one extreme position , to be changed upon actuation.



5.Spool center spool valves :
Open center - interconnects all ports - to remove pressure from end user to flow back into the tank
Closed center:- Closes all ports - pressure retained.
Tandem center: Blocks flow  from end user ports - but connects pressure port to tank at low pressure- used in series circuits.
Float Center: - Pressure maintained at pressure port- but removed from other ports - used commonly with pilot operated check valve circuits.



6.Rotary valve


Two stage valves
These are used to control fluids at high pressures , where the main valve is actuated by a pilot mechanism . The main purpose is to reduce pressure surges in the system and smooth operation. 
They can be incorporated with stroke limiting of main spool  or a throttle valve flow between pilot to main spool for smother transition , as shown below:


A pilot operated choke valve controlling spool is as below:

A symbolic  representation of various two stage valves is as below:

















2 comments:

  1. What to do with accumulation of knowledge? Pass it on. You have .Thank you
    Reply
  2. For the conformity of a control valve a circle calibrator or a weight calibrator can be used between 3-15psi.Check the valve position for 3psi which is to be 0 for a NC sort valves.In such way check the valve position for various ranges(6psi,9psi,12psi and 15psi).the valve position should be 0 for 3psi and half for 9 psi and completely opened for15psi.know get more information about Control Valve Calibration
    Reply
















Thursday 4 January 2018

Double acting cylinder Pneumatic Circuit

Double acting cylinder Pneumatic Circuit - single cycle
http://newengineeringpractice.blogspot.in/p/fuck.html
Extraction of the double acting cylinder is started by pressing the push button 1.2. After the cylinder has reached its front position the roller leaver valve 1.3 switches the main control valve 1.1 back to its initial position and the cylinder is reversing. The cycle can be restarted, when the cylinder has been completely retracted.
 from  http://newengineeringpractice.blogspot.in
By K.M Thiruvasagam


Double acting cylinder Pneumatic Circuit - multi cycle

Some elements e.g. roller lever valves may be actuated in their initial position. This is indicated by a cam, which actuates the roller lever of the valve.
Note: The position of limit switches is marked in the control diagram.


from http://newengineeringpractice.blogspot.in

By K.M Thiruvasagam
*******************************************

By K.M Thiruvasagam
*******************

Single-acting-cylinder-3by2-dcv



Double-acting-cylinder-3by2-dcv.jpg
Single-acting-cylinder-quick-exhaust-valve


Meter-In-Circuit-Pneumatic

Meter-Out-Circuit

Hydraulic-Circuits



Meter-In-And-Out-Hydraulic_Circuits